- Productbeschrijving
- Extra informatie
- Downloads
-
- RTD, TC, Ohm, or mV input
- Extremely high measurement accuracy
- 1.5 kVAC galvanic isolation
- Programmable sensor error value
- For DIN form B sensor head mounting
-
Technical Specifications Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-cond.) Protection degree (encl./terminal) IP68 / IP00 Mechanical specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm2 stranded wire Screw terminal torque 0.4 Nm Vibration IEC 60068-2-6 2...25 Hz ±1.6 mm 25...100 Hz ±4 g Common specifications Supply Supply voltage 7.2...35 VDC Internal power dissipation 25 mW…0.8 W Response time Response time (programmable) 1...60 s Voltage drop 7.2 VDC Warm-up time 5 min. Programming Loop Link Signal / noise ratio Min. 60 dB Accuracy Better than 0.05% of sel. range Signal dynamics, input 20 bit Signal dynamics, output 16 bit Effect of supply voltage change < 0.005% of span / VDC EMC immunity influence < ±0.5% of span Input specifications Common input specifications Max. offset 50% of selected max. value RTD input RTD type Pt100, Ni100, lin. R Cable resistance per wire 5 Ω (max.) Sensor current > 0.2 mA Effect of sensor cable resistance (3-wire) < 0.002 Ω / Ω Sensor error detection Yes Linear resistance input Linear resistance min....max. 0 Ω...5000 Ω TC Input Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC) < ±1.0°C Sensor error detection Yes Sensor error current: When detecting / else Nom. 33 μA / 0 μA Voltage input Measurement range -12...800 mV Min. measurement range (span) 5 mV Input resistance 10 MΩ Output specifications Current output Signal range 4…20 mA Min. signal range 16 mA Load (@ current output) ≤ (Vsupply - 7.2) / 0.023 [Ω] Load stability ≤ 0.01% of span / 100 Ω Sensor error indication Programmable 3.5…23 mA NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA Common output specifications Updating time 440 ms of span = of the presently selected range I.S. / Ex marking
ATEX II 3 G Ex nA [ic] IIC
T4...T6 Gc, II 3 G Ex ic
IIC T4...T6 Gc, II 3 D
Ex ic IIIC DcIECEx Ex nA [ic] IIC T4...T6
Gc, Ex ic IIC T4...T6
Gc, Ex ic IIIC DcObserved authority requirements EMC 2014/30/EU RoHS 2011/65/EU EAC TR-CU 020/2011 Approvals ATEX 2014/34/EU KEMA 10ATEX0002 X IECEx DEK 13.0035X INMETRO DEKRA 16.0013 X DNV-GL Marine Stand. f. Certific. No. 2.4 -
Documents:
File name Upload Date Size PR Electronics 5333D Datasheet 2019.3.11 0.46 MB PR Electronics 5333D Manual 2018.3.28 1.43 MB